Highpoint RocketRAID 2720 Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Schnittstellenkarten / Adapter Highpoint RocketRAID 2720 herunter. Highpoint RocketRAID 2720 Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Host Adapters User’s Guide

1 RocketRAID 2700 6Gb/s SAS/SATA Host Adapters User’s Guide Revision: 1.0 Date: December 2009 HighPoint Technol

Seite 2 - Copyright

10 J1 This jumper supports SAF-TE interface (I2C). 1.2 – RocketRAID 2722 Port2、Port3 These

Seite 3

11 2 - Installing the RocketRAID Host Adapter Note: Make sure the system is powered-off before installing the RocketRAID host adapter. The RocketRAI

Seite 4

12 RocketRAID BIOS Utility The RocketRAID 2700 card will display it's BIOS screen during the system's boot process. Press Control + H when

Seite 5 - HighPoint Technologies, Inc

13 BIOS Commands Create - this command is used to open the RAID Creation menu. Delete - this command will delete the selected RAID array. Add/R

Seite 6

14 Creating Arrays: Select Create from the toolbar and press Enter. 1. Use the arrow keys to select the RAID level and press ENTER. 2. Use t

Seite 7

15 3. On the Create menu, use the arrow keys to highlight the Select Devices item and press Enter. A device list will appear, and display all avail

Seite 8 - 2 - Kit Contents

16 7. Sector Size – Also known as “Variable Sector Size”. Use this option if you are using an older 32-bit Windows operating system. This allows o

Seite 9

17 4 - Adding/Remove Spare Disks This Add/Remove Spare command is used to assign a hard disk to act as a Spare Disk. Spare Disks are used to automat

Seite 10

18 HighPoint Software CD Each retail box includes a copy of the HighPoint Products Software CD. This CD can be used to generate driver diskettes, an

Seite 11 - 3 - Verifying Installation

19 Device Driver Installation – Windows Operating Systems We recommend visiting the RocketRAID download pages for the latest Windows Devic

Seite 12 - RocketRAID BIOS Utility

2 Copyright Copyright © 2009 HighPoint Technologies, Inc. This document contains materials protected by International Copyright Laws. Al

Seite 13 - 2 - Creating RAID Arrays

20 RocketRAID 2700 Windows Driver Installation Windows XP, 2003 Installing the RocketRAID driver for an existing Windows system After the operatin

Seite 14 - Creating Arrays:

21 3. Click on the “Include this location in the search” option, and click “Browse”. Browse to the location of the driver and click Next. 4. Wi

Seite 15

22 5. Click finish when prompted. When Windows asks to reboot the system, choose Yes. Installing the RocketRAID driver during a fresh Windows ins

Seite 16 - 3 – Deleting Arrays

23 RocketRAID 2700 Windows 7/Vista/Windows 2008 Driver Installation Installing the driver for an existing Windows 7, Vista and 2008 system 1. Inst

Seite 17 - 5 - Settings

24 4. Select “I don’t have disc, show me other options”. 5. and then select “Browse my computer for driver software”. .

Seite 18 - HighPoint Software CD

25 6. Browse to the location of the driver and click “Next”. 7. When asked: “Would you like to install this driver software?”, select “Install”.

Seite 19

26 8. Reboot the system when prompted. The RocketRAID host adapter will be ready for use after Windows reboots. Installing the driver during a f

Seite 20

27 Linux and FreeBSD Device Driver installation Binary and source driver updates are routinely posted for a variety of older Linux ope

Seite 21

28 HighPoint RAID Management Utilities (HRM) – Web GUI / CLI The HighPoint RAID Management Utility Suite, also known as “HRM”, includes

Seite 22

29 Debian/Ubuntu Linux Distributions – Installing the Web-based Management Utility For Debian/Ubuntu Linux distributions, you can use alien to conve

Seite 23

3 HIGHPOINT TECHNOLOGIES, INC... 5 HIGHPOINT ROCKETRAID 2700 SERIES – PCI-EXPRESS 2.0

Seite 24

30 1 - Installing the Web GUI (v1.5) - Windows Operating Systems (2000, XP, 2003, Vista, 2008, Windows 7) 1) After downloading the Web GUI, double-

Seite 25

31 2) The HighPoint Web RAID Management Service install screen will display. Click Next to continue: 3) Click Yes to install the Management util

Seite 26

32 4) Specify the Destination folder and click Next: Confirm the install location, and click Next:

Seite 27

33 5) Select the SAF-TE configuration file for the system’s chassis. If the system does not support SAF-TE, select the default option “Skip and Conf

Seite 28 - Management utility

34 7) Choose to enable or disable Remote Access. Remote access allows the card to be managed via a Web browser from a separate system. 8) Click

Seite 29 - Uninstalling the Utility

35 2 - Starting the Web GUI 1) Double-click the “HighPoint Web RAID Management” Icon on the the Desktop to start the Web GUI. The system’s default

Seite 30 - Vista, 2008, Windows 7)

36 3 - Web GUI – Icon Definitions The Rocket RAID Web GUI uses a variety of Icons to represent various states or functions. The followi

Seite 31

37 4 - Web GUI - Configuring an Array This guide assumes that the hard disks have already been installed into the external chassis, and attached to

Seite 32

38 Create an Array To create an array, select Manage – Array from the Web RAID Management Utility’s toolbar. This will open the Manage Array menu:

Seite 33

39 Foreground: The RAID initialization process will be set as high priority. The array cannot be utilized this procedure is complete, but the build

Seite 34

4 4 - Web GUI - Configuring an Array... 37 Initializ

Seite 35 - 2 - Starting the Web GUI

40 5 - Web GUI - Configuring Spare Disks The term “Spare Disk” refers to a hard disk, or dedicated disk space, that is used to rebuild a RAID array

Seite 36

41 2) Click “OK” when the pop-up window is displayed. This will add the disk to the Spare Pool. 3) To remove a Spare Disk from the Spare pool, cl

Seite 37

42 6 - Web GUI - Recovering an Array When a redundant array’s status is ”Critical”, fault tolerance is disabled. The array is can be used in this fo

Seite 38

43 2) Click “Add Disk”. 3) Select the desired drive and click “submit. 4) The Web GUI will initiate the rebuild procedure, and display a progre

Seite 39

44 7 - Web GUI - Maintaining RAID Arrays Regular scheduled RAID Maintenance is essential to data security. We recommend routine RAID v

Seite 40

45 Removing Tasks 1) From the task List, Check the box before the target Task and click “Delete”.

Seite 41

46 SHI – Storage Health Inspector The Storage Health Inspector section provides real-time device related information including temperature readings,

Seite 42

47 8 - Web GUI - Safeguarding your Array The RocketRAID Host Adapter provides a number of innovative maintenance and notification features

Seite 43

48 Enable Audible Alarm – enable or disable the card’s alarm. The alarm will sound if the a disk or array stops responding. Event Log Path – Use th

Seite 44

49 9 - Web GUI - Event Notification The RocketRAID 2700 host adapters will record Administrator activity or RAID related errors to the Web GUI’s E

Seite 45 - Removing Tasks

5 HighPoint Technologies, Inc. HighPoint Technologies, long recognized as a leader in mass storage technologies specializes in the design and manufac

Seite 46

50 Configuring SMTP (E-mail) Notification The Web GUI provides an SMTP notification system – this feature can be used to instruct the Web GUI to sen

Seite 47 - Automatic RAID Rebuilding

51 10 - Web GUI - Advanced RAID Functions (Windows VSS, OCE/ORLM) VSS – Variable Sector Size Variable Sector size allows you specify the sector size

Seite 48

52 2. After selecting the block size, the Web GUI will display a warning message: Select OK to continue. Click the “Create” button once more to c

Seite 49

53 5. Double-click “Administrative Tools”. 6. Double-Click “Computer Management”. 7. Under “Storage”, click on the folder icon labeled “Disk

Seite 50

54 Disk Management 8. Click “Next” to continue

Seite 51

55 9. Click “Finish” to continue. 10. Right-click the “Unallocated” box and select “New Partition”. 11. Partition and format the array as de

Seite 52

56 Online Capacity Expansion and RAID Level Migration (OCE/ORLM) OCE/ORLM allows you to add hard disks to an existing RAID array, and/or convert the

Seite 53

57 a) Target Name – The GUI will ask that you enter a “new” name for reference (the previous RAID configuration will be displayed

Seite 54

58 4. The Web GUI will notify you when the process starts. A progress bar will be displayed under the Status column of the Manage-Array menu. 5.

Seite 55

59 Customer Support If you encounter any problems while utilizing the RocketRAID host adapter, or have any questions about about this or any other H

Seite 56

6 HighPoint RocketRAID 2700 Series – PCI-Express 2.0 RocketRAID 2710/2720/2722 HOST ADAPTER The RocketRAID 2710/272x host adapters are high-perform

Seite 57

60 Thank You Thank you for purchasing the RocketRAID 2700 SATAII RAID Host adapter. We appreciate your support, and welcome any questions, comments o

Seite 58

61 FCC Part 15 Class B Radio Frequency Interference statement This equipment has been tested and found to comply with the limits for a Class B di

Seite 59 - Customer Support

7 1 - Features and Specifications Host Adapter Architecture  PCI-Express x8 (Gen2)  Support up to 4/8 SAS/SATA drives  1 Internal MiniSAS Conn

Seite 60 - Thank You

8 Operating System Support  Windows XP, 2003, Windows Vista, Windows 2008, Windows 7 (32 and 64-bit versions)  Linux (Fedora Core, Red Hat Enter

Seite 61

9 Hardware – Description and Installation 1.1-RocketRAID 2710/272x Host Adapter layout Illustration shows RocketRAID 2720 Port1、Po

Kommentare zu diesen Handbüchern